国产精品欧美日韩在线播放-亚洲国产日韩精品...-99久久国产综合精品女小说-加勒比亚洲国产成人精品

老化測(cè)試設(shè)備

咨詢熱線

18566398802
首頁(yè) > 標(biāo)準(zhǔn)大全 > ASTM G130-2020標(biāo)準(zhǔn)詳情
相關(guān)測(cè)試儀器

ASTM G130-2020

(該標(biāo)準(zhǔn)已經(jīng)被ASTM G130-2020替代)
  本頁(yè)面標(biāo)準(zhǔn)信息均來(lái)源于網(wǎng)絡(luò)收集,或由參與標(biāo)準(zhǔn)制定的供應(yīng)商提供,只作為參考使用。我們?cè)敢夂湍涣鰽STM G130-2020標(biāo)準(zhǔn)細(xì)節(jié)信息或ASTM G130-2020測(cè)試方法,歡迎致電【18566398802】

ASTM G130-2020標(biāo)準(zhǔn)介紹

ASTM G130-2020發(fā)行信息

標(biāo)準(zhǔn)號(hào)ASTM G130-2020

中文名 使用分光譜射度計(jì)校準(zhǔn)窄帶和寬帶紫外輻射計(jì)的標(biāo)準(zhǔn)試驗(yàn)方法

英文名 Standard Test Method for Calibration of Narrow- and Broad-Band Ultraviolet Radiometers Using a Spectroradiometer

發(fā)布日期2020

實(shí)施日期

廢止日期無(wú)

國(guó)際標(biāo)準(zhǔn)分類號(hào)17.180.20 (Colours and measurement of light)

發(fā)布單位US-ASTM

ASTM G130-2020適用范圍

1.1 This test method covers the calibration of ultraviolet light-measuring radiometers possessing either narrow- or broad-band spectral response distributions using either a scanning or a linear-diode-array spectroradiometer as the primary reference instrument. For transfer of calibration from radiometers calibrated by this test method to other instruments, Test Method E824 should be used.

NOTE 1:Special precautions must be taken when a diode-array spectroradiometer is employed in the calibration of filter radiometers having spectral response distributions below 320-nm wavelength. Such precautions are described in detail in subsequent sections of this test method.

1.2 This test method is limited to calibrations of radiometers against light sources that the radiometers will be used to measure during field use.

NOTE 2:For example, an ultraviolet radiometer calibrated against natural sunlight cannot be employed to measure the total ultraviolet irradiance of a fluorescent ultraviolet lamp.

1.3 Calibrations performed using this test method may be against natural sunlight, Xenon-arc burners, metal halide burners, tungsten and tungsten-halogen lamps, fluorescent lamps, etc.

1.4 Radiometers that may be calibrated by this test method include narrow-, broad-, and wide-band ultraviolet radiometers, and narrow-, broad, and wide-band visible-region-only radiometers, or radiometers having wavelength response distributions that fall into both the ultraviolet and visible regions.

NOTE 3:For purposes of this test method, narrow-band radiometers are those with Δλ ≤ 20 nm, broad-band radiometers are those with 20 nm ≤Δλ ≤ 70 nm, and wide-band radiometers are those with Δλ ≥ 70 nm.

NOTE 4:For purposes of this test method, the ultraviolet region is defined as the region from 285 to 400-nm wavelength, and the visible region is defined as the region from 400 to 750-nm wavelength. The ultraviolet region is further defined as being either UV-A with radiation of wavelengths from 315 to 400 nm, or UV-B with radiation from 285 to 315-nm wavelength.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

1.1本試驗(yàn)方法包括使用掃描或線性二極管陣列光譜輻射計(jì)作為主要參考儀器,對(duì)具有窄帶或?qū)拵Ч庾V響應(yīng)分布的紫外線測(cè)量輻射計(jì)進(jìn)行校準(zhǔn)。為了將通過(guò)本試驗(yàn)方法校準(zhǔn)的輻射計(jì)的校準(zhǔn)轉(zhuǎn)移到其他儀器,應(yīng)使用試驗(yàn)方法E824。

注1:當(dāng)二極管陣列光譜輻射計(jì)用于校準(zhǔn)光譜響應(yīng)分布低于320 nm波長(zhǎng)的濾波輻射計(jì)時(shí),必須采取特殊預(yù)防措施。在本試驗(yàn)方法的后續(xù)章節(jié)中詳細(xì)描述了此類預(yù)防措施。

1.2本試驗(yàn)方法僅限于針對(duì)現(xiàn)場(chǎng)使用期間輻射計(jì)將用于測(cè)量的光源對(duì)輻射計(jì)進(jìn)行校準(zhǔn)。

注2:例如,根據(jù)自然陽(yáng)光校準(zhǔn)的紫外線輻射計(jì)不能用于測(cè)量熒光紫外線燈的總紫外線輻照度。

1.3使用本試驗(yàn)方法進(jìn)行的校準(zhǔn)可針對(duì)自然陽(yáng)光、氙弧燃燒器、金屬鹵化物燃燒器、鎢和鹵鎢燈、熒光燈等進(jìn)行。

1.4可通過(guò)本試驗(yàn)方法校準(zhǔn)的輻射計(jì)包括窄帶、寬帶和寬帶紫外輻射計(jì),以及僅限窄帶、寬帶和寬帶可見(jiàn)光區(qū)域的輻射計(jì),或波長(zhǎng)響應(yīng)分布同時(shí)屬于紫外和可見(jiàn)光區(qū)域的輻射計(jì)。

注3:就本試驗(yàn)方法而言,窄帶輻射計(jì)為Δλ型≤ 20nm,寬帶輻射計(jì)為20nm輻射計(jì)≤Δλ ≤ 70 nm,寬帶輻射計(jì)為Δλ≥ 70納米。

注4:在本試驗(yàn)方法中,紫外線區(qū)域定義為波長(zhǎng)為285至400 nm的區(qū)域,可見(jiàn)光區(qū)域定義為波長(zhǎng)為400至750 nm的區(qū)域。紫外線區(qū)域進(jìn)一步定義為波長(zhǎng)為315至400 nm的UV-A或波長(zhǎng)為285至315 nm的UV-B。

1.5本標(biāo)準(zhǔn)并非旨在解決與其使用相關(guān)的所有安全問(wèn)題(如有)。本標(biāo)準(zhǔn)的使用者有責(zé)任在使用前建立適當(dāng)?shù)陌踩⒔】岛铜h(huán)境實(shí)踐,并確定監(jiān)管限制的適用性。

1.6本國(guó)際標(biāo)準(zhǔn)是根據(jù)世界貿(mào)易組織技術(shù)性貿(mào)易壁壘(TBT)委員會(huì)發(fā)布的《關(guān)于制定國(guó)際標(biāo)準(zhǔn)、指南和建議的原則的決定》中確立的國(guó)際公認(rèn)標(biāo)準(zhǔn)化原則制定的。

溫馨提醒:本ASTM G130-2020可能存在更新的版本,建議尋找ASTM G130-2020的發(fā)行商確認(rèn)。