1. SCOPE

This standard specifies accelerated test method for light resistance (*1) of non-metallic materials and products in automobile cabin using light-exposure apparatus with xenon-arc lamp (*2) (hereinafter call “Test apparatus”).

Note:

(*1) The property of resistance to variation of color, gloss, etc. under irradiation of light, and shall be distinguished from weather resistance, which is the property of resistance to variation to natural actions, such as out-door sunlight, wind, rain, etc.

(*2) Test apparatus capable of performing irradiation of an artificial light source closely resembling sunlight for examining part of the properties of light resistance in a short time.

2. DEFINITION OF TERMS

Definitions of main terms used in this standard shall be accordance with Table 1.

Table 1

Term

Definition

1)       Black panel temperature

(hereinafter call “B.P.T”)

The temperature indicated by a black panel thermometer attached to a rack or rotary board, which is representative for the surface temperature of test pieces.

2)       Xenon-arc lamp

An arc lamp which emits by xenon-arc discharge.

3)       Emission part

The part composed of a xenon-arc lamp and a filter.

3.TSET CONDITIONS

For evaluating variation of color, gloss, etc., conditions, such as temperature, humidity, irradiance, etc., which are effective on test results, shall be in accordance with Table 2.

Table 2

Item

Condition

1)       Temperature

B.P.T. 89±3%

2)       Relative humidity

50±5%RH

3)       Irradiance(*3)

48-100W/m2(within 300-400nm)

4)       Irradiance ratio

Irradiance of 320nm max. shall be under 1.5% of that of 300-400nm

5)       Irradiation method

Continuous irradiation

6)       Test period control

According to radiant exposure quantity

Note(*3): Selection of irradiance shall be effective on acceleration, however, irradiance also shall be effective on sample temperature and heat history. Appropriate irradiance is needed to be selected considering effect on sample by temperature.

4. APPARATUS AND PERFORMANCE

Test apparatus shall be constructed of an emission part, xenon-arc starting and stabilizing apparatus, irradiance adjusting apparatus, temperature adjust apparatus, test tank, humidity adjusting apparatus, test piece holder, cooling apparatus, instrumentation apparatus, etc.

4.1 Emission Part

4.1.1 Emission Part shall be as follows, according to clause 3:

1) Xenon-arc lamp: Xenon-arc lamps are long arc lamps of a.c. burning in which electrodes are sealed-in both ends of a quartz tube and xenon gas is sealed-in inside, and are used with performing forced water cooling or forced air cooling.

2) Filter: Filters are used for obtaining the required spectral characteristics and for cooling the xenon-arc lamp. For insulating the ultraviolet part, glass filters for ultraviolet-radiation insulation, running water, etc., are used.

3) Other: Based on the portion to be used, material superior in heat resistance, corrosion resistance, humidity resistance, or electric insulation shall be used.

4.1.2 Spectral characteristics of emission part

The xenon-arc lamp shall have a continuous spectrum at least over the wavelength range of 250 to 1200 nm, and shall have a similar spectral characteristics to glass-through-sunlight in combination with filter.

4.1.3 Irradiance of test piece surface

Irradiance of test piece surfaces shall be able to be set on any certain value within 48-100W/m2 at least over the wavelength range of 300 to 400 nm.

Also, spectral irradiances of test piece surfaces in the wavelength of 300 to 400nm shall be indicated for each type of test apparatus. Further, the irradiance in other wavelength ranges or the spectral irradiance at s specific wavelength should also be marked upon agreement between the parties concerned. The measuring method is to be in accordance with the annex of JIS B 7754.

4.1.4 Tolerance in irradiance during operation

It shall be capable of maintaining ±10% of the set irradiance.

4.1.5 Tolerance in irradiance of test pieces surfaces

The difference of irradiances of test piece surfaces due to the position must not exceed 10% of the maximum value.

4.1.6 Irradiation method

As a rule, a certain constant irradiance shall be kept continuously during operation.

4.2 Irradiance Adjusting Apparatus

The irradiance adjusting apparatus is an apparatus to correct the attenuation of radiation energy accompanying the use of a xenon-arc lamp and filter, measuring the irradiance in the wavelength of 300 to 400 nm, and shall be provided with one of the following conditions:

1) It shall be capable of manual adjustment of the lamp power to make the irradiance constant.

2) It shall be capable of automatic control of the lamp power to make the irradiance constant.

3) It shall be capable of manual adjustment of the lamp power stepwise accoding to the time of use.

4.3Black Panel Thermometer

Black panel thermometer is so structured that the heat sensitive body, bimetal, platinum resistor, thermistor, thermoelectric couple, etc., is attached coincident with the center of the metal plate and is adhered tightly to the heat sensitive body protecting tube.

Remarks: Structures and dimensions shall be in accordance with 5.7(2) and Attached Fig.1. Type A of JIS B 7754.

4.4 Test Tank

Temperature and humidity in test tank shall be as follows:

1) B.P.T. at the position of test piece shall be 89±3℃.

Remarks: Temperature will be different depending on the combination of xenon-arc lamp type and filter.

2) Relative humidity

It shall favorably be capable of keeping relative humidity 50±5% under the temperature specified in 1). Further, relative humidity shall be measured at the point close to and inside the exit of test tank.

4.5 Other

Items unspecified in the foregoing clauses, such as test tank, xenon-arc starting and stabilizing apparatus, temperature adjusting apparatus, humidity adjusting apparatus, test piece holder, cooling apparatus, instrumentation apparatus, etc., shall be in accordance with JIB B 7754.

5. TEST PIECE

5.1Dimensions of Test Piece

Irradiation area of test piece shall be 30 mm min in vertical direction and over 30mm min horizontal direction, and thickness shall be determined according to agreement to agreement between the parties concerned. Further, when test piece has urethane foam backing layer as part construction, density and composition, etc. of the layer shall be determined between the parties concerned.

5.2 Other

In case of test piece with texture direction, such as fabrics, etc., attachment direction relative to test apparatus shall be indicated.

6. PROCEDURE

6.1 Attach test piece on test piece holder firmly so that it won’t drop. Further, when backing material like urethane foam is attached on backside of test piece, the backside shall be contracted with backing material as tightly as possible so that it shall not become loose.

6.2Set test piece holders with test pieces attached on a rack or a rotary board without gaps between the holders. When there are some test piece holders without test pieces, put white-colored papers, aluminum plates, stainless steel plates, etc., on all of the holder in order to keep heat equilibrium inside test tank.

6.3 Select a certain irradiance within 48-100W/m2 in the wavelength of 300-400nm, and adjust test apparatus so that the selected irradiance shall be kept constant during exposure.

6.4 Adjust B.P.T during exposure within 89±3℃ by temperature adjusting apparatus.

6.5 Adjust humidity during exposure within 50±5% RH.

6.6 In case of broad samples, their position shall favorably be replaced at certain intervals for better test accuracy.

Remarks: Radiant exposure quantity can be calculated by the following formula:

Radiant exposure quantity (KJ/m2) = Irradiance (W/m2)×Time(Hr)×3.6

Applicable standards

JIS B 7754

JASO M 346

Reference Standard

 

<<Ref.

Applicable Standard

 

<<Ref.

HES D6601-99A PDF資料

以下標準信息來自互聯(lián)網(wǎng)搜索整理,僅供學習使用,可以免費下載。

歡迎了解專業(yè)工程師提供的HES D6601-99A標準解讀,請加微信。

溫馨提醒:本HES D6601-99A可能存在更新的版本,建議尋找HES D6601-99A的發(fā)行商確認。

符合 HES D6601-99A 標準的
老化試驗箱

  • 氙燈老化箱圖片 氙燈老化箱氙燈老化箱

    Q-SUN Xe-1-B是一款適合小型實驗室的氙燈老化箱,其命名規(guī)程B指的是改型號的產(chǎn)品具有背部噴淋功能,這意味著在SAE部分標準的測試中尤其有用。

    Q-SUN Xe-1-B 馬上詢價
  • 氙燈老化試驗箱圖片 氙燈老化試驗箱氙燈老化試驗箱

    Q-SUN Xe-3-HSE氙燈老化試驗箱具有全光譜光照功能、濕度控制以及噴淋功能,其命名規(guī)則為濕度控制(H)、噴淋(S)。

    Q-SUN Xe-3-HSE 馬上詢價
  • 氙燈加速老化試驗箱圖片 氙燈加速老化試驗箱氙燈加速老化試驗箱

    Q-sun Xe-1-BCE氙燈加速老化試驗箱配有全光譜氙弧燈、太陽眼輻照度控制系統(tǒng),該型號的氙燈加速老化試驗箱同時具有背部噴功能。

    Q-sun Xe-1-BCE 馬上詢價
  • 氙燈耐候試驗機圖片 氙燈耐候試驗機氙燈耐候試驗機

    Q-SUN Xe-1-SCE氙燈耐候試驗機是一款支持水噴淋功能和制冷功能的氙燈加速老化設備

    Q-SUN Xe-1-SCE 馬上詢價
  • 氙燈老化試驗機圖片 氙燈老化試驗機氙燈老化試驗機

    Q-SUN Xe-3-HCE是一款具有全光譜光照模擬、濕度控制以及制冷功能的氙燈老化試驗機,其命名規(guī)則為濕度控制(H)、制冷功能(C)。

    Q-SUN Xe-3-HCE 馬上詢價
  • 氙燈耐氣候試驗箱圖片 氙燈耐氣候試驗箱氙燈耐氣候試驗箱

    Q-SUN Xe-3-HDSE氙燈耐氣候試驗箱具有濕度控制、以及雙噴淋功能,其命名規(guī)則為濕度(H)、雙噴淋(D)、噴淋(S)。

    Q-SUN Xe-3-HDSE 馬上詢價
  • 氙燈耐候試驗箱圖片 氙燈耐候試驗箱氙燈耐候試驗箱

    Q-SUN Xe-3-HSCE氙燈耐候試驗箱同時具有濕度控制、噴淋以及制冷功能,其命名規(guī)則為濕度(H)、噴淋(S)、制冷(C)。

    Q-SUN Xe-3-HSCE 馬上詢價
  • 氙燈加速老化箱圖片 氙燈加速老化箱氙燈加速老化箱

    Q-SUN Xe-3-HE氙燈加速老化箱是一款經(jīng)濟的氙燈加速老化箱,具備有濕度控制功能,但是該型號的產(chǎn)品不具備水噴淋功能。

    Q-SUN Xe-3-HE 馬上詢價
近期文章